{"id":3898,"date":"2021-05-26T15:24:34","date_gmt":"2021-05-26T18:24:34","guid":{"rendered":"https:\/\/electrographics.com.br\/news\/?p=3898"},"modified":"2021-05-26T15:27:22","modified_gmt":"2021-05-26T18:27:22","slug":"atualizacao-update-1-electro-graphics-serie-2021","status":"publish","type":"post","link":"https:\/\/electrographics.com.br\/news\/atualizacao-update-1-electro-graphics-serie-2021\/","title":{"rendered":"Atualiza\u00e7\u00e3o Update 1 Electro Graphics S\u00e9rie 2021"},"content":{"rendered":"<p>A atualiza\u00e7\u00e3o Update 1 inclui as \u00faltimas atualiza\u00e7\u00f5es para os produtos da Electro Graphics S\u00e9rie 2021.<br \/>\n\u2022 SOLergo<br \/>\n\u2022 Linha Amp\u00e8re<br \/>\n\u2022 CADs el\u00e9tricos (linha CADelet, iDEA e Eplus)<br \/>\n\u2022 Cablo<br \/>\n\u2022 Utilidades<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"color: #0070c0;\">Ambiente gr\u00e1fico (linha CADelet, iDEA, Eplus)<\/span><\/strong><\/h2>\n<p><span style=\"color: #000000;\"><strong>Multifolha<\/strong><\/span><br \/>\nFoi atualizado o recurso de substitui\u00e7\u00e3o autom\u00e1tica do bloco de t\u00edtulo que n\u00e3o era reconhecido corretamente quando o nome do bloco continha caracteres mai\u00fasculos e min\u00fasculos.<\/p>\n<p><span style=\"color: #000000;\"><strong>Bornes<\/strong><\/span><br \/>\nAtualizado a atribui\u00e7\u00e3o do n\u00famero do borne durante a opera\u00e7\u00e3o de an\u00e1lise do diagrama com a op\u00e7\u00e3o Pin borne = n\u00famero do fio, no caso de bornes de um \u00fanico pino seccionando o fio (ver op\u00e7\u00e3o de numera\u00e7\u00e3o dos fios Dist\u00e2ncia de posi\u00e7\u00e3o do borne). Nesta condi\u00e7\u00e3o particular, o borne foi atribu\u00eddo ao n\u00famero de um dos fios conectados ao borne, sem ser determin\u00e1vel. Agora o n\u00famero do primeiro fio \u00e9 atribu\u00eddo, determinado de acordo com a ordem posicional dos fios imposta para o diagrama.<\/p>\n<p><span style=\"color: #000000;\"><strong>Desenho dos dutos<\/strong><\/span><br \/>\nAtualiza\u00e7\u00e3o da fun\u00e7\u00e3o de desenho de dutos, na modalidade n\u00e3o orientada para o acoplamento de s\u00edmbolos: durante o acoplamento entre dutos com diferentes eleva\u00e7\u00f5es, ocorria a representa\u00e7\u00e3o de se\u00e7\u00f5es verticais pr\u00f3ximo a jun\u00e7\u00e3o.<\/p>\n<p><span style=\"color: #000000;\"><strong>Gest\u00e3o de Redes<\/strong><\/span><br \/>\n\u2022 Melhorias no gerenciamento da dist\u00e2ncia frontal a montante para usu\u00e1rios a jusante verticais.<br \/>\n\u2022 Melhorias no roteamento dos cabos em eletrocalhas\/canaletas com m\u00faltiplos compartimentos.<\/p>\n<p><span style=\"color: #000000;\"><strong>Legenda de s\u00edmbolos<\/strong><\/span><br \/>\nFoi atualizada o posicionamento dos s\u00edmbolos na tabela de legendas gerada atrav\u00e9s do comando LEGENDA, no caso de s\u00edmbolos com duas linhas de descri\u00e7\u00e3o, nos par\u00e2metros de configura\u00e7\u00e3o da Biblioteca de S\u00edmbolos.<\/p>\n<p><span style=\"color: #000000;\"><strong>Tabela de materiais<\/strong><\/span><br \/>\nAtualizado do desenho CAD das tabelas personalizadas do Tabula: algumas configura\u00e7\u00f5es de impress\u00e3o n\u00e3o eram aplicadas corretamente.<\/p>\n<p><span style=\"color: #000000;\"><strong>Diagrama unifilar<\/strong><\/span><br \/>\n\u2022 Melhorias no c\u00f3digo dos dispositivos de prote\u00e7\u00e3o diferencial, do tipo MT+D, o qual n\u00e3o era reportado nos s\u00edmbolos inseridos no diagrama unifilar. A aus\u00eancia do c\u00f3digo no s\u00edmbolo n\u00e3o extraia o item para lista de materiais do Tabula, e n\u00e3o era exibido tamb\u00e9m o dispositivo no desenho do layout do quadro. O c\u00f3digo agora \u00e9 inserido no s\u00edmbolo principal relativo ao dispositivo de prote\u00e7\u00e3o.<br \/>\n\u2022 Ao realizar o desenho do diagrama com a op\u00e7\u00e3o de Desenhar linha PE ativa, os usu\u00e1rios do tipo motor agora s\u00e3o desenhados com um deslocamento de forma a evitar a sobreposi\u00e7\u00e3o e os elementos DPS s\u00e3o conectados ao coletor de aterramento.<\/p>\n<p><span style=\"color: #000000;\"><strong>Salvar em PDF<\/strong><\/span><br \/>\nOs documentos anexados aos materiais, em formato pdf com prote\u00e7\u00e3o por senha, n\u00e3o podem ser vinculados \u00e0 impress\u00e3o do pdf.<br \/>\nAl\u00e9m disso, no painel Marcadores do visualizador de PDF do Adobe Acrobat Reader, os arquivos em pdf com Prote\u00e7\u00e3o por senha para autoriza\u00e7\u00e3o s\u00e3o adicionados \u00e0 lista de Documentos anexados, enquanto os arquivos em pdf com Prote\u00e7\u00e3o por senha para abertura de documentos n\u00e3o s\u00e3o.<br \/>\nAo final da impress\u00e3o, aparece uma janela com a lista dos arquivos que n\u00e3o podem ser abertos ou com prote\u00e7\u00e3o por senha para a abertura do documento; a lista exibida pode ser copiada para a \u00e1rea de transfer\u00eancia.<\/p>\n<p><span style=\"color: #000000;\"><strong>Numera\u00e7\u00e3o dos pinos dos bornes<\/strong><\/span><br \/>\nAtualiza\u00e7\u00e3o da fun\u00e7\u00e3o Numera\u00e7\u00e3o de borne e conectores, ao utilizar essa fun\u00e7\u00e3o ocorria um erro de identifica\u00e7\u00e3o por c\u00f3digo, localiza\u00e7\u00e3o e fun\u00e7\u00e3o dos bornes e conectores quando possu\u00eda no nome do projeto o caractere &#8216;.&#8217; (ponto).<\/p>\n<p><span style=\"color: #000000;\"><strong>Layout do quadro<\/strong><\/span><br \/>\nO layout do quadro tamb\u00e9m foi atualizado, agora \u00e9 representado corretamente o n\u00famero de elementos para conectores com c\u00f3digo principal vinculado \u00e0 um ou mais acess\u00f3rios.<\/p>\n<p><span style=\"color: #000000;\"><strong>Par\u00e2metros de configura\u00e7\u00e3o<\/strong><\/span><br \/>\nMelhorias na janela de Par\u00e2metros de configura\u00e7\u00e3o&gt; Formato de documento, referente as listas suspensas do painel Cores, ao qual n\u00e3o exibiam as cores corretas dos layers das folhas (para s\u00edmbolos, textos e fios), e sim o valor \u201cdo layer\u201d.<\/p>\n<p><span style=\"color: #000000;\"><strong>Configura\u00e7\u00e3o do ambiente gr\u00e1fico<\/strong><\/span><br \/>\nMelhorias na configura\u00e7\u00e3o da escala do s\u00edmbolo, caso o conjunto do separador decimal seja o caractere v\u00edrgula.<\/p>\n<p><span style=\"color: #000000;\"><strong>Refer\u00eancias cruzadas &#8211; Cross reference<\/strong><\/span><br \/>\nMelhorias na gera\u00e7\u00e3o da refer\u00eancia cruzada dos s\u00edmbolos.<\/p>\n<p><strong>Marcadores de conte\u00fado dos trechos de dutos<\/strong><br \/>\nAtualizado a fun\u00e7\u00e3o dos marcadores sint\u00e9ticos dos trechos de dutos, em trechos de linhas terminais.<\/p>\n<p><span style=\"color: #000000;\"><strong>Lista de materiais<\/strong><\/span><br \/>\nAtualizada a contagem dos elementos de jun\u00e7\u00e3o das eletrocalhas na extra\u00e7\u00e3o da lista de materiais para o Tabula.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/CADs_Lista-de-materiais.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3895 aligncenter\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/CADs_Lista-de-materiais.png\" alt=\"\" width=\"600\" height=\"424\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/CADs_Lista-de-materiais.png 600w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/CADs_Lista-de-materiais-509x360.png 509w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"color: #0070c0;\">Cablo<\/span><\/strong><\/h2>\n<p><span style=\"color: #000000;\"><strong>Diagrama de detalhes do cabo<\/strong><\/span><br \/>\nAtualiza\u00e7\u00e3o da fun\u00e7\u00e3o Desenhar o diagrama com detalhes do cabo com a op\u00e7\u00e3o Estender a representa\u00e7\u00e3o do cabo tamb\u00e9m para os conectores conectados de forma que a representa\u00e7\u00e3o n\u00e3o inclua os cabos conectados na extremidade oposta em rela\u00e7\u00e3o ao cabo selecionado para o desenho.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"color: #0070c0;\">Linha Amp\u00e8re<\/span><\/strong><\/h2>\n<p><span style=\"color: #000000;\"><strong>Inversores VFD<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Melhorias na verifica\u00e7\u00e3o de curto-circuito da linha de alimenta\u00e7\u00e3o de um motor na presen\u00e7a de um inversor VFD.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Impress\u00e3o dos ajustes das prote\u00e7\u00f5es<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Atualizado a impress\u00e3o de informa\u00e7\u00f5es dos ajustes para prote\u00e7\u00f5es que n\u00e3o permitem realizar a calibra\u00e7\u00e3o.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Ambiente de trabalho<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Otimizado a velocidade de carregar os projetos.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Malha<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Atualiza\u00e7\u00e3o da classifica\u00e7\u00e3o de usu\u00e1rios presente na lista do painel Projeto.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Usu\u00e1rio terminal n\u00e3o ativado<\/strong><\/span><br \/>\nMelhorias na altera\u00e7\u00e3o da pot\u00eancia de usu\u00e1rios terminais que estavam desativados ao executar o recalculo da rede.<\/p>\n<p><span style=\"color: #000000;\"><strong>Conex\u00f5es entre fase<\/strong><\/span><br \/>\nAtualiza\u00e7\u00e3o da conex\u00e3o de fase em usu\u00e1rios monof\u00e1sicos subjacentes \u00e0 uma alimenta\u00e7\u00e3o trif\u00e1sica, que ocasionavam a altera\u00e7\u00e3o da liga\u00e7\u00e3o automaticamente.<\/p>\n<p><span style=\"color: #000000;\"><strong>Verifica\u00e7\u00f5es<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">O nome dos usu\u00e1rios sem especifica\u00e7\u00e3o da Zona, tamb\u00e9m foi atualizado na janela de Verifica\u00e7\u00f5es, os mesmos apresentavam o nome incompleto.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Tipo de linha<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Atualizado o c\u00e1lculo da se\u00e7\u00e3o da linha ap\u00f3s a altera\u00e7\u00e3o do tipo de linha de Barramento para Cabo.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Edi\u00e7\u00e3o de usu\u00e1rios selecionados<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Na janela de edi\u00e7\u00e3o dos dados de prote\u00e7\u00e3o de v\u00e1rios usu\u00e1rios selecionados, a op\u00e7\u00e3o Presen\u00e7a de prote\u00e7\u00e3o de backup a montante agora est\u00e1 desabilitada, pois \u00e9 uma edi\u00e7\u00e3o que n\u00e3o \u00e9 permitida; anteriormente, embora a opera\u00e7\u00e3o n\u00e3o fosse permitida, o campo estava habilitado.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Balanceamento da rede com conversores AC\/DC<\/strong><\/span><br \/>\nAtualizado a fun\u00e7\u00e3o de balanceamento de rede para conversores AC\/DC, geradores em CC e motores ass\u00edncronos CA, o equil\u00edbrio das correntes de opera\u00e7\u00e3o n\u00e3o estava sendo representado corretamente.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/Amp\u00e8re_Balanceamento-das-fases.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3894\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/Amp\u00e8re_Balanceamento-das-fases.png\" alt=\"\" width=\"600\" height=\"425\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/Amp\u00e8re_Balanceamento-das-fases.png 600w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/Amp\u00e8re_Balanceamento-das-fases-508x360.png 508w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"color: #0070c0;\">EgLink<\/span><\/strong><\/h2>\n<p><span style=\"color: #000000;\"><strong>Inicializa\u00e7\u00e3o do projeto<\/strong><\/span><br \/>\nMelhorias na inicializa\u00e7\u00e3o de projetos abertos na nuvem BIM 360.<\/p>\n<p><span style=\"color: #000000;\"><strong>An\u00e1lise da rede<\/strong><\/span><br \/>\nOs tempos de an\u00e1lise da rede de passagem de cabos por dutos\/eletrocalhas foram aprimorados, especialmente na presen\u00e7a de um grande n\u00famero de trechos que n\u00e3o foram conectados.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"color: #0070c0;\">SOLergo<\/span><\/strong><\/h2>\n<p><span style=\"color: #000000;\"><strong>C\u00e1lculo da queda de tens\u00e3o para cabos em alum\u00ednio<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Aprimorado o c\u00e1lculo da queda de tens\u00e3o dos cabos ao utilizar de cabos de alum\u00ednio de acordo com as novas tabelas CEI UNEL 35023:2020; anteriormente, era avaliado em cerca de 1,5 vezes.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Documenta\u00e7\u00e3o<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">Atualiza\u00e7\u00e3o da impress\u00e3o da tabel<\/span>a de rastreadores no Relat\u00f3rio geral para projetos com um \u00fanico inversor no sistema e m\u00faltiplos rastreadores; agora a tabela exibe todos os rastreadores.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/SOLergo_Relat\u00f3rio-geral.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3893\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/SOLergo_Relat\u00f3rio-geral.png\" alt=\"\" width=\"600\" height=\"424\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/SOLergo_Relat\u00f3rio-geral.png 600w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/SOLergo_Relat\u00f3rio-geral-509x360.png 509w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"color: #0070c0;\">Todos os produtos<\/span><\/strong><\/h2>\n<p><span style=\"color: #000000;\"><strong>Utilidade de tradu\u00e7\u00e3o de textos<\/strong><\/span><br \/>\nO utilit\u00e1rio de tradu\u00e7\u00e3o autom\u00e1tica de texto foi atualizado com o Microsoft Bing Translator 3.0. A vers\u00e3o anterior 2.0 logo n\u00e3o ser\u00e1 utilizada pela Microsoft, portanto, se voc\u00ea n\u00e3o instalar esta atualiza\u00e7\u00e3o, a fun\u00e7\u00e3o de tradu\u00e7\u00e3o autom\u00e1tica n\u00e3o poder\u00e1 mais ser utilizada.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2021\/05\/S\u00e9rie-2021-BRA-Update-1.pdf\" target=\"_blank\" rel=\"noopener\">Para ver o arquivo em PDF clique aqui.<\/a><\/p>\n<p>&nbsp;<\/p>\n<table id=\"templateBody\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td class=\"bodyContent\" valign=\"top\">\n<div><span style=\"color: #000000; font-family: Tahoma;\"><i>Servi\u00e7o de Marketing T\u00e9cnico<\/i><\/span><\/div>\n<div><span style=\"color: #000080; font-family: Tahoma;\"><b>Electro Graphics &amp; Hiper Energy<\/b><\/span><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>A atualiza\u00e7\u00e3o Update 1 inclui as \u00faltimas atualiza\u00e7\u00f5es para os produtos da Electro Graphics S\u00e9rie 2021. \u2022 SOLergo \u2022 Linha Amp\u00e8re \u2022 CADs el\u00e9tricos (linha CADelet, iDEA e Eplus) \u2022 Cablo \u2022 Utilidades &nbsp; Ambiente gr\u00e1fico (linha CADelet, iDEA, Eplus) Multifolha Foi atualizado o recurso de substitui\u00e7\u00e3o autom\u00e1tica do bloco de t\u00edtulo que n\u00e3o era [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3890,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-3898","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-atualizacoes"],"_links":{"self":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/3898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/comments?post=3898"}],"version-history":[{"count":7,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/3898\/revisions"}],"predecessor-version":[{"id":3912,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/3898\/revisions\/3912"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/media\/3890"}],"wp:attachment":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/media?parent=3898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/categories?post=3898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/tags?post=3898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}