{"id":6332,"date":"2025-04-03T17:31:02","date_gmt":"2025-04-03T20:31:02","guid":{"rendered":"https:\/\/electrographics.com.br\/news\/?p=6332"},"modified":"2025-04-03T17:37:37","modified_gmt":"2025-04-03T20:37:37","slug":"serie-2025-update-1","status":"publish","type":"post","link":"https:\/\/electrographics.com.br\/news\/serie-2025-update-1\/","title":{"rendered":"S\u00e9rie 2025 Update 1"},"content":{"rendered":"\n<p>O Update 1 inclui as \u00faltimas atualiza\u00e7\u00f5es para os produtos da Electro Graphics S\u00e9rie 2025.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>SOLergo <\/li>\n\n\n\n<li>Linha Amp\u00e8re <\/li>\n\n\n\n<li>CADs el\u00e9tricos (linha CADelet, iDEA e Eplus) <\/li>\n\n\n\n<li>Cablo <\/li>\n\n\n\n<li>Utilidades <\/li>\n<\/ul>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color has-medium-font-size wp-elements-3ddfc56d503ee6bef166b97fcae92fda\" style=\"color:#198cd9\"><strong>Ambiente gr\u00e1fico (linha CADelet, iDEA e Eplus)<\/strong> <\/p>\n\n\n\n<p><strong>Otimiza\u00e7\u00e3o do acesso aos dicion\u00e1rios com arquivos compartilhados<\/strong> <br>Foram introduzidas otimiza\u00e7\u00f5es em rela\u00e7\u00e3o ao gerenciamento de dicion\u00e1rio e opera\u00e7\u00f5es de tradu\u00e7\u00e3o com arquivos compartilhados em rede. Os dados do dicion\u00e1rio em uso s\u00e3o carregados e armazenados temporariamente na mem\u00f3ria para acelerar o acesso a eles durante as opera\u00e7\u00f5es de tradu\u00e7\u00e3o. Em caso de altera\u00e7\u00f5es contextuais por v\u00e1rios operadores no mesmo dicion\u00e1rio, use o bot\u00e3o &#8220;Atualizar&#8221; para sincronizar manualmente o dicion\u00e1rio atual com os dados contidos na rede.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"149\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/CADs-eletricos_Dicionario.png\" alt=\"\" class=\"wp-image-6334\"\/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Melhorias no m\u00e9todo de classifica\u00e7\u00e3o de componentes na &#8220;Tabela resumida do quadro&#8221;<\/strong><br>O m\u00e9todo de atribui\u00e7\u00e3o do \u00edndice de classifica\u00e7\u00e3o dos componentes exibidos na \u201cTabela resumida do quadro\u201d, uma fun\u00e7\u00e3o do co-mando de desenho \u201cLayout do quadro\u201d, foi aprimorado. O \u00edndice \u00e9 determinado com base na posi\u00e7\u00e3o exata dos modelos do layout do quadro dispostos no desenho.<\/p>\n\n\n\n<p><strong>Gest\u00e3o do PLC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Valores dos atributos personalizados (etiquetas do usu\u00e1rio) foram inclu\u00eddos na pesquisa ativa.<\/li>\n\n\n\n<li>Melhorias na exporta\u00e7\u00e3o das informa\u00e7\u00f5es para planilha. Em alguns casos espec\u00edficos, ocorria uma anomalia ap\u00f3s uma altera\u00e7\u00e3o na ordem das colunas.<\/li>\n<\/ul>\n\n\n\n<p><strong>Outras melhorias<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Atualiza\u00e7\u00e3o do comando Imprimir Folhas (da linha de comando NSTAMPE) no CADelet com AutoCAD 2021-2024. Em algumas condi\u00e7\u00f5es, uma mensagem de erro impedia a conclus\u00e3o do comando.<\/li>\n\n\n\n<li>Funcionalidade Salvar como PDF\/A foi aprimorada para impress\u00f5es de multi-folhas em todos os ambientes CAD.<\/li>\n\n\n\n<li>Melhorias na representa\u00e7\u00e3o do diagrama unifilar com a presen\u00e7a de um comutador de rede: em algumas condi\u00e7\u00f5es, um comuta-dor era representado duas vezes.<\/li>\n\n\n\n<li>Foram removidas mensagens contradit\u00f3rias de licen\u00e7a ausente que apareciam em algumas condi\u00e7\u00f5es ao criar diagramas de blo-cos de arquivos de usu\u00e1rio usando a Gest\u00e3o Sin\u00f3tica.<\/li>\n\n\n\n<li>Atualiza\u00e7\u00e3o da linha de t\u00edtulo da Tabela de percursos dos condutos.<\/li>\n\n\n\n<li>Revis\u00e3o da classifica\u00e7\u00e3o do Tabula, em alguns casos ocorria uma perda da classifica\u00e7\u00e3o atribu\u00edda as localiza\u00e7\u00f5es ao atualizar o esquema do Tabula.<\/li>\n\n\n\n<li>Cablo: ao realizar uma altera\u00e7\u00e3o no projeto no Cablo, quando um borne multiplano \u00e9 alterado para um borne de um \u00fanico plano, os atributos do s\u00edmbolo do borne presente no desenho s\u00e3o atualizados.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color has-medium-font-size wp-elements-170981e2aa086fbf6765daa00ca1b54c\" style=\"color:#198cd9\"><strong>Linha Amp\u00e8re<\/strong><\/p>\n\n\n\n<p><strong>Regula\u00e7\u00e3o m\u00e1xima das espiras do transformador<br><\/strong>O limite m\u00e1ximo de regula\u00e7\u00e3o das espiras do transformador passou a ser um dado espec\u00edfico para cada transformador, personaliz\u00e1vel na ficha t\u00e9cnica do mesmo (Propriedades do usu\u00e1rio). Em Propriedades &#8211; Normas e Constantes Globais o valor comum a todo o sistema de regula\u00e7\u00e3o n\u00e3o est\u00e1 mais presente.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"494\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Propriedade-do-transformador.png\" alt=\"\" class=\"wp-image-6336\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Propriedade-do-transformador.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Propriedade-do-transformador-401x360.png 401w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>C\u00e1lculo da Curva de capability P\/Q e V\/Q<br><\/strong>A interface principal foi revisada, com uma reorganiza\u00e7\u00e3o dos comandos divididos em 4 setores horizontais:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Op\u00e7\u00f5es de impress\u00e3o na parte superior<\/li>\n\n\n\n<li>Op\u00e7\u00f5es de curva P\/Q<\/li>\n\n\n\n<li>Op\u00e7\u00f5es de curva V\/Q<\/li>\n\n\n\n<li>Comandos de desenho<\/li>\n<\/ul>\n\n\n\n<p>As mudan\u00e7as mais significativas foram feitas na curva de capacidade V\/Q, que agora \u00e9 capaz de lidar com as curvas de tens\u00e3o parametrizadas fornecidas pelos fabricantes de geradores\/inversores, permitindo um estudo correto conforme a tens\u00e3o varia.<br>A segunda mudan\u00e7a mais importante \u00e9 a possibilidade de exportar os resultados (pontos de opera\u00e7\u00e3o) para uma planilha, ou dire-tamente para o Excel, permitindo posterior processamento pelos projetistas.<\/p>\n\n\n\n<p class=\"has-text-align-left\"><strong>C\u00e1lculo da curva de capability P\/Q (Avan\u00e7ado, para Amp\u00e8re Evolution)<br><\/strong>A impress\u00e3o da curva de capabiliy P\/Q foi revisada reorganizando as principais informa\u00e7\u00f5es no n\u00edvel de fornecimento dos gerado-res envolvidos. Os limites de sub e sobre-excita\u00e7\u00e3o agora s\u00e3o exibidos, facilmente compar\u00e1veis com a pot\u00eancia reativa trocada. Os dados do gerador informam a pot\u00eancia aparente e a pot\u00eancia ativa importante, que corresponde \u00e0 pot\u00eancia de regula\u00e7\u00e3o.<br>Veja a figura em anexo.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"688\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability.png\" alt=\"\" class=\"wp-image-6338\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-288x360.png 288w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Acreditamos ser importante ressaltar a import\u00e2ncia de conhecer a real metodologia de regula\u00e7\u00e3o dos pontos de opera\u00e7\u00e3o dos geradores\/inversores do sistema de produ\u00e7\u00e3o. Ap\u00f3s uma solicita\u00e7\u00e3o para operar em um determinado fator de pot\u00eancia e, portanto, trocar uma quantidade Q de pot\u00eancia reativa com a rede, como os geradores s\u00e3o regulados? Todos no mesmo \u00e2ngulo (modo s\u00edncrono) ou independentes um do outro (modo ass\u00edncrono)?<br>Portanto, a regula\u00e7\u00e3o s\u00edncrona ou ass\u00edncrona \u00e9 t\u00e3o importante quanto o tipo de curva, pois ela mesma determina a \u00e1rea de pot\u00eancia que o conjunto de geradores pode cobrir. \u00c9 importante comunicar isso \u00e0 distribuidora de energia porque esse \u00e9 um dos par\u00e2metros de resposta \u00e0 pot\u00eancia reativa necess\u00e1ria.<\/p>\n\n\n\n<p><strong>C\u00e1lculo da curva de capability V\/Q (avan\u00e7ado, para Amp\u00e8re Evolution)<br><\/strong>O Amp\u00e8re Evolution tamb\u00e9m calcula a curva de capability V\/Q, que fornece a amplitude de Q\/Pnd que o sistema de gera\u00e7\u00e3o \u00e9 ca-paz de fornecer \u00e0 rede quando a tens\u00e3o de alimenta\u00e7\u00e3o varia.<br>Para garantir a estabilidade da rede, os geradores n\u00e3o devem apenas ser capazes de produzir energia ativa, mas \u00e9 essencial que eles tamb\u00e9m produzam a pot\u00eancia reativa exigida pela rede.<br>Estabelecida como refer\u00eancia a pot\u00eancia m\u00e1xima produzida Pnd na tens\u00e3o nominal Vn, o gr\u00e1fico fornece a capacidade do sistema de produzir, com a varia\u00e7\u00e3o da tens\u00e3o, a pot\u00eancia reativa em sub e sobre-excita\u00e7\u00e3o, com os limites exibidos na figura.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"329\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ.png\" alt=\"\" class=\"wp-image-6342\"\/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Esses limites, assim como a curva de capability P\/Q, dependem do tipo de sistema (fotovoltaico, e\u00f3lico) e da tens\u00e3o de alimenta-\u00e7\u00e3o (Tipo 1, tipo 2), e por esse motivo nos referimos mais uma vez aos Anexos A.17 e A.68 da Terna, ou do \u00f3rg\u00e3o de fornecimento respons\u00e1vel, para escolher os valores corretos.<br>O software cria a curva V\/Q repetindo o estudo da curva de capability P\/Q em diferentes tens\u00f5es de alimenta\u00e7\u00e3o, da tens\u00e3o mais baixa (normalmente 0.9 Vn) para a tens\u00e3o mais alta (normalmente 1.1 Vn), e lendo os valores de \u2013Q e +Q correspondentes \u00e0 emiss\u00e3o Pnd dos geradores\/inversores.<br>Para geradores\/inversores associados a uma fam\u00edlia de curvas P\/Q com valores que s\u00e3o em fun\u00e7\u00e3o da tens\u00e3o, o software proces-sa o valor interpolado entre as duas curvas mais pr\u00f3ximas da tens\u00e3o de opera\u00e7\u00e3o.<br>As correntes capacitivas absorvidas pelas linhas tamb\u00e9m s\u00e3o em fun\u00e7\u00e3o da tens\u00e3o, portanto, o aumento da tens\u00e3o aumenta o efeito capacitivo das linhas e, consequentemente, +Q aumenta, movendo o gr\u00e1fico para a direita, como pode ser visto na figura.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"770\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ02.png\" alt=\"\" class=\"wp-image-6344\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ02.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ02-257x360.png 257w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>No exemplo acima, a curva V\/Q plotada em azul intercepta a \u00e1rea preenchida em vermelho, que representa o limite m\u00ednimo neces-s\u00e1rio.<br>Neste ponto, um m\u00e9todo para aumentar a amplitude da pot\u00eancia reativa \u00e9 regular a pot\u00eancia Pnd ativa dos geradores\/inversores, fazendo-os trabalhar em \u00e1reas com maior pot\u00eancia reativa m\u00e1xima. \u00c9 poss\u00edvel simular esta solu\u00e7\u00e3o pedindo ao software para cal-cular a curva V\/Q em uma porcentagem reduzida de Pnd, por exemplo 98%, conforme mostrado na figura, com o valor definido no campo Curva V\/Q calculada em % de Pnd.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"379\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Propriedades-curva-capability02.png\" alt=\"\" class=\"wp-image-6348\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Propriedades-curva-capability02.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Propriedades-curva-capability02-522x360.png 522w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Neste ponto, voc\u00ea pode avaliar a possibilidade de ajustar a pot\u00eancia ativa dos geradores\/inversores para trabalhar em um valor menor (por exemplo 98% como testado no exemplo) at\u00e9 obter uma solu\u00e7\u00e3o ideal para o sistema.<br>Certamente, nas avalia\u00e7\u00f5es t\u00e9cnicas\/econ\u00f4micas ser\u00e1 necess\u00e1rio encontrar um compromisso justo com a distribuidora de energia. \u00c9 sempre importante lembrar que o estudo realizado com o software \u00e9 uma simula\u00e7\u00e3o matem\u00e1tica com m\u00faltiplos graus de aproxi-ma\u00e7\u00e3o que juntos contribuem para o resultado final.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"620\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ04.png\" alt=\"\" class=\"wp-image-6346\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ04.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ04-319x360.png 319w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Por fim, ressaltamos que o estudo pode ser realizado em uma faixa de tens\u00e3o personaliz\u00e1vel utilizando os comandos V\/Vnom m\u00ed-nimo e V\/Vnom m\u00e1ximo. Para o c\u00e1lculo da curva de capability V\/Q, a faixa de tens\u00e3o \u00e9 dividida em v\u00e1rias partes, proporcionalmente \u00e0 Qualidade do desenho selecionada.<br>De fato, o n\u00famero de amostras \u00e9 relatado no documento na se\u00e7\u00e3o Pontos da curva, que relatamos para maior clareza.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"318\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Curva-capability-VQ05.png\" alt=\"\" class=\"wp-image-6347\"\/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Impress\u00e3o das curvas e Exporta\u00e7\u00e3o da tabela de pontos<br><\/strong>Os dois comandos da Curva de capability realizam a an\u00e1lise correspondente e abrem a visualiza\u00e7\u00e3o de impress\u00e3o. Tamb\u00e9m possui uma lista suspensa para:<\/p>\n\n\n\n<p>Impress\u00e3o da Curva de capability: ap\u00f3s a an\u00e1lise, \u00e9 exibido uma lista suspensa \u201cImprimir\u201d que permite executar os seguintes comandos Visualiza\u00e7\u00e3o, Imprimir, Salvar PDF, Agrupar, Configurar p\u00e1gina ou Dados do projeto.<\/p>\n\n\n\n<p>Exportar a tabela de pontos de capability: ap\u00f3s a an\u00e1lise, \u00e9 poss\u00edvel escolher entre Microsoft Excel, OpenOffice, Planilha (*.xls, *.xlsx), para exportar as informa\u00e7\u00f5es.<br>Esta fun\u00e7\u00e3o \u00e9 muito \u00fatil, pois fornece todos os valores do estudo da curva de capability P\/Q e V\/Q, tanto em valor absoluto quanto em porcentagem.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"280\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Ampere_Excel-curva-capability.png\" alt=\"\" class=\"wp-image-6350\"\/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Outras melhorias<br><\/strong>Melhorias na importa\u00e7\u00e3o de um gerador fotovoltaico criado com otimizadores em configura\u00e7\u00e3o mista, com m\u00f3dulo fotovoltaico individual e duplo.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color has-medium-font-size wp-elements-173b37c34263d5739083bd3f6143c17c\" style=\"color:#198cd9\"><strong>SOLergo<\/strong><\/p>\n\n\n\n<p><strong>Sele\u00e7\u00e3o autom\u00e1tica da localiza\u00e7\u00e3o<br><\/strong>Agora os dados clim\u00e1ticos podem ser importados do PVGIS ap\u00f3s definir o endere\u00e7o do local atrav\u00e9s do Google Maps do SOLergo.<br>Para definir automaticamente a localiza\u00e7\u00e3o exata: na p\u00e1gina Dados gerais do sistema, utilize o bot\u00e3o Mapa para selecionar a localiza\u00e7\u00e3o do sistema via Google Maps. Em seguida, confirme a solicita\u00e7\u00e3o para Importar dados clim\u00e1ticos do PVGIS: dessa forma, o local definido corresponde \u00e0 posi\u00e7\u00e3o selecionada. Os dados de altitude s\u00e3o carregados somente se o local estiver presente no arquivo de dados clim\u00e1ticos.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"383\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/SOLergo_Importacao-dos-dados-do-PVGIS.png\" alt=\"\" class=\"wp-image-6335\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/SOLergo_Importacao-dos-dados-do-PVGIS.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/SOLergo_Importacao-dos-dados-do-PVGIS-517x360.png 517w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Outras melhorias<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Revis\u00e3o geral para melhor exibi\u00e7\u00e3o de imagem em telas UltraHD 4K: adapta\u00e7\u00e3o tamb\u00e9m ao gr\u00e1fico de irradi\u00e2ncia e documenta\u00e7\u00e3o.<\/li>\n\n\n\n<li>Atualiza\u00e7\u00e3o das refer\u00eancias normativas do relat\u00f3rio geral.<\/li>\n\n\n\n<li>Melhorias na representa\u00e7\u00e3o da pot\u00eancia nominal do sistema no caso da presen\u00e7a de um sistema de armazenamento no lado CC bidirecional.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color has-medium-font-size wp-elements-b869d7975203f0808cd88b7ca5c410c7\" style=\"color:#198cd9\"><strong>Todos os produtos<\/strong><\/p>\n\n\n\n<p><strong>Modelos de documenta\u00e7\u00e3o predefinidos<br><\/strong>Modelos de documenta\u00e7\u00e3o predefinidos s\u00e3o selecionados automaticamente durante a impress\u00e3o.<br>Para definir um modelo padr\u00e3o, selecione o comando Predefinido no menu de contexto. Os modelos predefinidos s\u00e3o destacados com uma marca de sele\u00e7\u00e3o.<br>Por padr\u00e3o, o modelo padr\u00e3o \u00e9 o primeiro modelo em cada grupo de documentos.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"617\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Relatorio-predefinido.png\" alt=\"\" class=\"wp-image-6351\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Relatorio-predefinido.png 550w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Relatorio-predefinido-321x360.png 321w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Gerenciamento de usu\u00e1rios<br><\/strong>Atualiza\u00e7\u00e3o do Gerenciamento de Usu\u00e1rios ao armazenar arquivos em um servi\u00e7o de servidor de rede, como MySQL ou MS SQL Server.<\/p>\n\n\n\n<p><strong>Revis\u00e3o dos pedidos<br><\/strong>Atualiza\u00e7\u00e3o das listas suspensas do operador na guia de revis\u00e3o de um pedido.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-330e958a wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size\" style=\"font-size:12px\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2025\/04\/Serie-2025_Update-1.pdf\" style=\"border-radius:5px;background-color:#0070c0\" target=\"_blank\" rel=\"noreferrer noopener\">Arquivo em PDF<\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-font-size is-style-fill\" style=\"font-size:12px\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.electrographics.com.br\/contato\" style=\"border-radius:5px;background-color:#0070c0\" target=\"_blank\" rel=\"noreferrer noopener\">Fale conosco<\/a><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-cyan-bluish-gray-color has-alpha-channel-opacity has-cyan-bluish-gray-background-color has-background is-style-wide\"\/>\n\n\n\n\n","protected":false},"excerpt":{"rendered":"<p>O Update 1 inclui as \u00faltimas atualiza\u00e7\u00f5es para os produtos da Electro Graphics S\u00e9rie 2025. Ambiente gr\u00e1fico (linha CADelet, iDEA e Eplus) Otimiza\u00e7\u00e3o do acesso aos dicion\u00e1rios com arquivos compartilhados Foram introduzidas otimiza\u00e7\u00f5es em rela\u00e7\u00e3o ao gerenciamento de dicion\u00e1rio e opera\u00e7\u00f5es de tradu\u00e7\u00e3o com arquivos compartilhados em rede. Os dados do dicion\u00e1rio em uso s\u00e3o [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":6368,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-6332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-atualizacoes"],"_links":{"self":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/6332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/comments?post=6332"}],"version-history":[{"count":10,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/6332\/revisions"}],"predecessor-version":[{"id":6372,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/6332\/revisions\/6372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/media\/6368"}],"wp:attachment":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/media?parent=6332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/categories?post=6332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/tags?post=6332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}