{"id":6907,"date":"2026-06-18T16:39:21","date_gmt":"2026-06-18T19:39:21","guid":{"rendered":"https:\/\/electrographics.com.br\/news\/?p=6907"},"modified":"2026-06-19T16:07:26","modified_gmt":"2026-06-19T19:07:26","slug":"nova-nr-10-adeque-seus-projetos-com-o-software-ampere","status":"publish","type":"post","link":"https:\/\/electrographics.com.br\/news\/nova-nr-10-adeque-seus-projetos-com-o-software-ampere\/","title":{"rendered":"Nova NR 10: Adeque seus Projetos com o Software Amp\u00e8re"},"content":{"rendered":"\n<p>O cen\u00e1rio da seguran\u00e7a el\u00e9trica no Brasil acaba de mudar drasticamente. A publica\u00e7\u00e3o da <strong>Portaria MTE n\u00ba 737 <\/strong>trouxe a t\u00e3o esperada reformula\u00e7\u00e3o da <strong>NR 10<\/strong>. Com foco total na harmoniza\u00e7\u00e3o com o <strong>Gerenciamento de Riscos Ocupacionais (GRO\/PGR)<\/strong>, a nova norma eleva o rigor t\u00e9cnico e estabelece novos par\u00e2metros obrigat\u00f3rios para profissionais e empresas do setor.<\/p>\n\n\n\n<p><strong>O que muda com a nova NR 10 (Portaria MTE 737)?<\/strong><\/p>\n\n\n\n<p>A principal mudan\u00e7a \u00e9 a integra\u00e7\u00e3o obrigat\u00f3ria do Prontu\u00e1rio de Instala\u00e7\u00f5es El\u00e9tricas (PIE) ao Programa de Gerenciamento de Riscos (PGR) da empresa. Isso exige que cada <strong>mem\u00f3ria de c\u00e1lculo<\/strong>, <strong>diagrama unifilar<\/strong> e <strong>estudo de seletividade <\/strong>seja diretamente indexado aos riscos ocupacionais de cada setor.<\/p>\n\n\n\n<p><strong>Como adequar os projetos el\u00e9tricos ao GRO\/PGR exigido pela norma?<\/strong><\/p>\n\n\n\n<p>A adequa\u00e7\u00e3o exige a emiss\u00e3o de relat\u00f3rios din\u00e2micos de engenharia que comprovem a seletividade da prote\u00e7\u00e3o, o <strong>c\u00e1lculo exato da energia incidente<\/strong> <strong>de<\/strong> <strong>Arc Flash <\/strong>e a robustez da malha de aterramento, mitigando riscos legais e operacionais.<\/p>\n\n\n\n<div style=\"height:6px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table style=\"width: 100%; max-width: 1000px; margin: 20px auto; border-collapse: collapse; font-family: sans-serif; text-align: left; border: 1px solid #e2e8f0;\">\n  <thead>\n    <tr style=\"background-color: #1a365d; color: #ffffff;\">\n      <th style=\"padding: 15px; font-size: 15px; font-weight: bold; width: 25%;\">Requisito da Nova NR 10<\/th>\n      <th style=\"padding: 15px; font-size: 15px; font-weight: bold; width: 38%;\">Impacto Direto no Projeto El\u00e9trico<\/th>\n      <th style=\"padding: 15px; font-size: 15px; font-weight: bold; width: 37%;\">Como o Software Amp\u00e8re Resolve<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr style=\"border-bottom: 1px solid #e2e8f0; background-color: #ffffff;\">\n      <td style=\"padding: 15px; font-size: 14px; font-weight: bold; color: #1a365d; vertical-align: top;\">Integra\u00e7\u00e3o com GRO\/PGR<\/td>\n      <td style=\"padding: 15px; font-size: 14px; color: #334155; vertical-align: top; line-height: 1.5;\">Necessidade de invent\u00e1rio de riscos el\u00e9tricos mapeado e detalhado por zona t\u00e9cnica.<\/td>\n      <td style=\"padding: 15px; font-size: 14px; color: #334155; vertical-align: top; line-height: 1.5;\">Emiss\u00e3o automatizada de relat\u00f3rios t\u00e9cnicos de conformidade estruturados para o PGR.<\/td>\n    <\/tr>\n    <tr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f8fafc;\">\n      <td style=\"padding: 15px; font-size: 14px; font-weight: bold; color: #1a365d; vertical-align: top;\">Rigor em Engenharia de Mitiga\u00e7\u00e3o<\/td>\n      <td style=\"padding: 15px; font-size: 14px; color: #334155; vertical-align: top; line-height: 1.5;\">Obrigatoriedade de simula\u00e7\u00e3o realista de curtos-circuitos e seletividade t\u00e9cnica.<\/td>\n      <td style=\"padding: 15px; font-size: 14px; color: #334155; vertical-align: top; line-height: 1.5;\">C\u00e1lculo preciso de correntes de curto-circuito em malhas de BT\/MT e ferramentas de coordena\u00e7\u00e3o de prote\u00e7\u00e3o.<\/td>\n    <\/tr>\n    <tr style=\"background-color: #ffffff;\">\n      <td style=\"padding: 15px; font-size: 14px; font-weight: bold; color: #1a365d; vertical-align: top;\">An\u00e1lise de Energia Incidente<\/td>\n      <td style=\"padding: 15px; font-size: 14px; color: #334155; vertical-align: top; line-height: 1.5;\">Exig\u00eancia de defini\u00e7\u00e3o exata das vestimentas e EPIs com base no risco de arco el\u00e9trico.<\/td>\n      <td style=\"padding: 15px; font-size: 14px; color: #334155; vertical-align: top; line-height: 1.5;\">M\u00f3dulo integrado de c\u00e1lculo de Arc Flash totalmente alinhado com as especifica\u00e7\u00f5es t\u00e9cnicas da ABNT NBR 17227.<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\n\n\n\n<div style=\"height:6px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Como o Software Amp\u00e8re Auxilia os Projetistas Frente \u00e0 Nova NR 10?<\/strong><\/p>\n\n\n\n<p>O <strong>Amp\u00e8re <\/strong>foi desenvolvido especificamente para automatizar e conferir precis\u00e3o cir\u00fargica aos estudos de engenharia el\u00e9trica mais complexos, incluindo os c\u00e1lculos de curto-circuito, seletividade e perigo de arco el\u00e9trico (Arc Flash). Veja como ele responde diretamente \u00e0s exig\u00eancias da nova norma:<\/p>\n\n\n\n<p><strong>1. Atendimento Pleno \u00e0 Recente ABNT NBR 17227 e Normas Internacionais<\/strong><\/p>\n\n\n\n<p>O Amp\u00e8re realiza estudos de Arc Flash aplicando rigorosamente os algoritmos das principais refer\u00eancias normativas exigidas pelo mercado nacional e internacional:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ABNT NBR 17227: <\/strong>A norma nacional para avalia\u00e7\u00e3o do perigo de arco el\u00e9trico.<\/li>\n\n\n\n<li><strong>IEEE 1584-2018:<\/strong> O guia padr\u00e3o global para c\u00e1lculos de energia incidente.<\/li>\n\n\n\n<li><strong>NFPA 70E:<\/strong> Refer\u00eancia m\u00e1xima para pr\u00e1ticas de seguran\u00e7a el\u00e9trica no ambiente de trabalho.<\/li>\n\n\n\n<li><strong>Stokes e OSHA:<\/strong> Modelos matem\u00e1ticos e diretrizes regulat\u00f3rias essenciais para complementar a an\u00e1lise em diferentes n\u00edveis de tens\u00e3o e configura\u00e7\u00f5es.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"509\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Arc-Flash-1024x509.png\" alt=\"\" class=\"wp-image-6917\" style=\"width:550px\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Arc-Flash-1024x509.png 1024w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Arc-Flash-640x318.png 640w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Arc-Flash-768x382.png 768w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Arc-Flash-1536x763.png 1536w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Arc-Flash.png 1680w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>2. Otimiza\u00e7\u00e3o de Tempos de Interrup\u00e7\u00e3o e Seletividade<\/strong><\/p>\n\n\n\n<p>Para cumprir a exig\u00eancia da Nova NR 10 de selecionar &#8220;tempos de interrup\u00e7\u00e3o muito curtos&#8221;, o projetista n\u00e3o pode recorrer a adivinha\u00e7\u00f5es. No Amp\u00e8re, voc\u00ea realiza o <strong>Estudo de Coordena\u00e7\u00e3o e Seletividade <\/strong>de forma visual e integrada. Ao alterar o ajuste de um rel\u00e9 ou disjuntor na curva tempo-corrente, o software recalcula instantaneamente a energia incidente resultante daquele tempo de atua\u00e7\u00e3o. Isso permite refinar os ajustes da prote\u00e7\u00e3o para reduzir o n\u00edvel de <em>cal\/cm\u00b2<\/em> ao menor patamar poss\u00edvel, garantindo um projeto seguro e em total conformidade com a norma.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"545\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Estudo-de-Protecao-1024x545.png\" alt=\"\" class=\"wp-image-6919\" style=\"width:550px;height:auto\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Estudo-de-Protecao-1024x545.png 1024w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Estudo-de-Protecao-640x341.png 640w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Estudo-de-Protecao-768x409.png 768w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Estudo-de-Protecao-1536x817.png 1536w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Estudo-de-Protecao.png 1650w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>3. Dimensionamento T\u00e9cnico de Vestimentas<\/strong><\/p>\n\n\n\n<p>A nova NR 10 refor\u00e7a que as vestimentas de trabalho devem ser adequadas \u00e0s influ\u00eancias t\u00e9rmicas do arco el\u00e9trico. Com os relat\u00f3rios gerados pelo Amp\u00e8re, o projetista consegue especificar com precis\u00e3o milim\u00e9trica a categoria da vestimenta e o <strong>ATPV <\/strong>m\u00ednimo necess\u00e1rio para cada painel ou barramento do sistema, evitando tanto a subprote\u00e7\u00e3o do trabalhador quanto o superdimensionamento (que gera custos desnecess\u00e1rios e desconforto t\u00e9rmico).<\/p>\n\n\n\n<p><strong>4. Emiss\u00e3o de Etiquetas de Sinaliza\u00e7\u00e3o de Arc Flash prontas<\/strong><\/p>\n\n\n\n<p>O software n\u00e3o entrega apenas n\u00fameros brutos. Ele gera automaticamente as etiquetas de advert\u00eancia prontas para impress\u00e3o, contendo a energia incidente calculada, os limites de aproxima\u00e7\u00e3o (fronteiras de seguran\u00e7a) e os EPIs recomendados. \u00c9 a engenharia de projeto entregando a solu\u00e7\u00e3o pronta para a gest\u00e3o de seguran\u00e7a (PGR) do cliente final.<\/p>\n\n\n\n<p>A nova NR 10 (Portaria 737\/2026) j\u00e1 \u00e9 uma realidade e concede um prazo de transi\u00e7\u00e3o para que empresas e profissionais se adaptem. Projetar sem considerar um estudo robusto de Arc Flash tornou-se um risco t\u00e9cnico, \u00e9tico e jur\u00eddico.<\/p>\n\n\n\n<p>Utilizar o <strong>Amp\u00e8re <\/strong>eleva o patamar dos seus projetos el\u00e9tricos. Mais do que entregar diagramas unifilares, voc\u00ea passa a entregar<strong> seguran\u00e7a quantific\u00e1vel<\/strong>, garantindo que seus clientes operem plantas industriais e comerciais protegidas por engenharia de ponta.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-94bc23d7 wp-block-group-is-layout-flex\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"507\" src=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Documentacao-Arc-Flash-1024x507.png\" alt=\"\" class=\"wp-image-6918\" style=\"width:550px;height:auto\" srcset=\"https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Documentacao-Arc-Flash-1024x507.png 1024w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Documentacao-Arc-Flash-640x317.png 640w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Documentacao-Arc-Flash-768x381.png 768w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Documentacao-Arc-Flash-1536x761.png 1536w, https:\/\/electrographics.com.br\/news\/wp-content\/uploads\/2026\/06\/Ampere_Documentacao-Arc-Flash.png 1689w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Quer preparar seus projetos para a Nova NR 10? <\/strong><a href=\"https:\/\/www.electrographics.com.br\/demo\" data-type=\"link\" data-id=\"https:\/\/www.electrographics.com.br\/demo\" target=\"_blank\" rel=\"noreferrer noopener\">Entre em contato conosco e agende uma demonstra\u00e7\u00e3o gratuita do software Amp\u00e8re!<\/a><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-small-font-size\"><strong>Fonte oficial da nova NR-10:<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\">Para conferir o texto integral das mudan\u00e7as regulat\u00f3rias, acesse diretamente a <a href=\"https:\/\/www.in.gov.br\/web\/dou\/-\/portaria-mte-n-737-de-29-de-maio-de-2026-709524662\" target=\"_blank\" rel=\"noreferrer noopener\"><em>Portaria MTE n\u00ba 737\/2026 publicada no Di\u00e1rio Oficial da Uni\u00e3o<\/em>.<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-cyan-bluish-gray-color has-alpha-channel-opacity has-cyan-bluish-gray-background-color has-background is-style-wide\"\/>\n\n\n\n<p class=\"has-small-font-size\"><strong><em>Artigo preparado e revisado pelo Team Electro Graphics Brasil<\/em><\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-330e958a wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background has-custom-font-size wp-element-button\" style=\"border-radius:5px;background-color:#0070c0;font-size:12px\">Fale conosco<\/a><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>O cen\u00e1rio da seguran\u00e7a el\u00e9trica no Brasil acaba de mudar drasticamente. A publica\u00e7\u00e3o da Portaria MTE n\u00ba 737 trouxe a t\u00e3o esperada reformula\u00e7\u00e3o da NR 10. Com foco total na harmoniza\u00e7\u00e3o com o Gerenciamento de Riscos Ocupacionais (GRO\/PGR), a nova norma eleva o rigor t\u00e9cnico e estabelece novos par\u00e2metros obrigat\u00f3rios para profissionais e empresas do [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":6903,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"class_list":["post-6907","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aprofundamento"],"_links":{"self":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/6907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/comments?post=6907"}],"version-history":[{"count":21,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/6907\/revisions"}],"predecessor-version":[{"id":6940,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/posts\/6907\/revisions\/6940"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/media\/6903"}],"wp:attachment":[{"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/media?parent=6907"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/categories?post=6907"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/electrographics.com.br\/news\/wp-json\/wp\/v2\/tags?post=6907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}